Volume of qualifying spills and wastewater discharges by classification and affected ecosystem
Measurement answer
What this metric measures
Reports volumes of qualifying spills and wastewater discharges, classified by spill scheme and affected ecosystem, where the reported events exceed applicable standards.
Specification
Metric specification
- Result format
- Structured table
- Unit
- cubic metres (m³) — source-defined reporting unit
- Reporting basis
- Reporting period
- Aggregation
- Total volume, disaggregated by applicable national or company spill classification and type of ecosystem affected
- Pillar
- Environmental
- Topic
- Pollution incidents and wastewater discharges
- Controlled domain
- Pollution
- Entity type
- Metric
Reporting boundary
Diesel, paints, solvents, toxic chemicals and wastewater discharges from the reporting organization that exceed applicable local regulatory or international standards
Verified source occurrences
Framework coverage
This is one canonical metric. The bindings below show every verified framework occurrence without creating duplicate metric pages. Edition, disclosure, role, and relationship remain source-specific.
- Adopting DisclosureSource evidence
TNFD sector guidance
- Publisher
- Taskforce on Nature-related Financial Disclosures
- Edition
- Final English sector guidance collection through August 2026 (17 documents)
- Requirement
- Not Specified
- Relationship
- Defines Disclosure
- Mapping outcome
- Direct Evidence
- Source locator
- TNFD Additional Sector Guidance: Engineering, construction and real estate, Version 1.0, January 2025, Section 3.2, Table 13, p.77 | Additional sector guidance – Engineering, construction and real estate, Version 1.0 (January 2025), page 77, section 3.2, Table 13
- Adopting DisclosureEH.C2.0
TNFD sector guidance
- Publisher
- Taskforce on Nature-related Financial Disclosures
- Edition
- Version 1.0, January 2025
- Requirement
- Conditional
- Relationship
- Maps Source Identity
- Mapping outcome
- Published
- Source locator
- Additional sector guidance – Engineering, construction and real estate, Version 1.0 (January 2025), page 77, section 3.2, Table 13
- Adopting DisclosureRE.C2.0
TNFD sector guidance
- Publisher
- Taskforce on Nature-related Financial Disclosures
- Edition
- Version 1.0, January 2025
- Requirement
- Conditional
- Relationship
- Maps Source Identity
- Mapping outcome
- Published
- Source locator
- Additional sector guidance – Engineering, construction and real estate, Version 1.0 (January 2025), page 77, section 3.2, Table 13
Value structure
Dimensions and units
- Unit
- cubic metres (m³) — source-defined reporting unit
- Reporting basis
- Reporting period
Unit meaning: Values use cubic metres (m³) under the disclosed TNFD sector-guidance method, reporting period and boundary.
Table fields and units
- material or discharge type
- spill classification scheme and classification
- affected ecosystem type
- applicable standard adhered to
- volume (m³)
Published dimensions
- material or discharge type: diesel, paints, solvents, toxic chemicals or wastewater discharge
- spill classification: applicable national or company classification scheme
- affected ecosystem type
- applicable local regulatory or international standard
Calculation method
Formula information
- Status
- Specified
- Formula type
- Sum
Formula
For each material or discharge type, spill classification and affected ecosystem, report the sum of volumes for spills and wastewater discharges exceeding the applicable local regulatory or international standard.Apply the source-defined TNFD sector-guidance method within the stated reporting boundary. The candidate provides a directly reportable quantitative outcome with an explicit cubic-metre unit, qualifying threshold, required disaggregation and affected-ecosystem dimension. It must remain distinct from Fishing oil and fuel-waste spills because the population, qualification test, material scope and required ecosystem/classification dimensions differ. None of the shortlisted metrics has the same scope, threshold and dimensional requirements.
Variables
| Symbol | Variable | Definition | Unit |
|---|---|---|---|
V_{m,c,e} | Qualifying spill or discharge volume | Total volume of diesel, paint, solvent, toxic-chemical spill or wastewater discharge of material type m, classification c and affected ecosystem e that exceeds the stated applicable standard. | m³ |
Verified sources
Evidence and status sources
Sustopedia checked each record-specific claim directly against primary publisher material. Labels distinguish current measurement authority from future compatibility and corroborative, legal, edition, or method status context. Corroborative evidence can support a stated limitation but cannot establish the core measurement by itself.
Measurement evidence
- Measurement evidenceChecked 30 August 2026
TNFD additional sector guidance collection
- Publisher
- Taskforce on Nature-related Financial Disclosures
- Edition
- Final English sector guidance collection through August 2026 (17 documents)
- Locator
- TNFD Additional Sector Guidance: Engineering, construction and real estate, Version 1.0, January 2025, Section 3.2, Table 13, p.77 | Additional sector guidance – Engineering, construction and real estate, Version 1.0 (January 2025), page 77, section 3.2, Table 13
Supports: The official TNFD sector guidance supports the identity, boundary and method basis of “Volume of qualifying spills and wastewater discharges by classification and affected ecosystem”.
Open official source
Use with context
Interpretation boundaries
Method disclosures required
Source-edition basis: TNFD sector guidance, Final English sector guidance collection through August 2026 (17 documents).
- Identify the local regulatory or international standard used to determine whether each spill or discharge exceeds the applicable threshold.
- Identify the national or company spill classification scheme used, where applicable.
- Disclose the type of ecosystem affected for each reported classification.
- State the measurement basis used to quantify reported volumes in cubic metres.
Record-specific limitations
- Only spills and wastewater discharges exceeding applicable local regulatory or international standards are within scope.
- The applicable classification scheme may differ by jurisdiction or company and must be identified by the reporting organization.
- The source does not provide a single universal threshold or a prescribed ecosystem taxonomy.
Interpret this metric with the stated reporting boundary, period convention, value shape, and unit. Results prepared with different boundaries or conventions may not be directly comparable.
Measurement evidence supports the core record-specific claims described above. Corroborative evidence can support limitations, while compatibility and status sources provide their separately labelled context. None of these cards by itself determines an organisation's legal applicability, filing readiness, assurance status, or compliance conclusion.