Search Sustopedia

MetricClimate targets and net-zero transition

Scope 2 electricity consumption hourly matched with low-carbon electricity

Measurement answer

What this metric measures

Scope 2 electricity consumption hourly matched with low-carbon electricity is a future-effective SBTi Version 2.0 result. It preserves the applicable company population, reporting boundary, period, denominator and required disaggregation without importing source prose.

Specification

Metric specification

Result format
Structured table
Unit
% — percentage of the compatible denominator
Reporting basis
The annual reporting period or applicable target, validation or OER cycle; base, target, cumulative and current-period observations remain separately identified.
Aggregation
Calculate within each activity pool and time-matching interval; aggregate only by summing matched and total electricity quantities before recomputing the percentage.
Pillar
Environmental
Topic
Climate targets and net-zero transition
Controlled domain
Climate and greenhouse gases
Entity type
Metric

Reporting boundary

Electricity consumption within each significant activity pool that is eligible for hourly matching with low-carbon electricity.

Verified source occurrences

Framework coverage

This is one canonical metric. The bindings below show every verified framework occurrence without creating duplicate metric pages. Edition, disclosure, role, and relationship remain source-specific.

  • Adopting Disclosure

    SBTi Corporate Net-Zero Standard v2.0

    Source evidence
    Publisher
    Science Based Targets initiative
    Edition
    Corporate Net-Zero Standard Version 2.0, June 2026; effective 1 February 2027
    Requirement
    Not Specified
    Relationship
    Defines Disclosure
    Mapping outcome
    Direct Evidence
    Source locator
    C32.2, PDF page 63; C32.5, PDF pages 63, 64
    Open official framework source
  • Adopting Disclosure

    SBTi Corporate Net-Zero Standard v2.0

    scope2-hourly-matching-share
    Publisher
    Science Based Targets initiative
    Edition
    Corporate Net-Zero Standard Version 2.0, June 2026; effective 1 February 2027
    Requirement
    Conditional
    Relationship
    Maps Source Identity
    Mapping outcome
    Published
    Source locator
    C32.2; PDF page 63 | C32.5; PDF pages 63, 64
    Open official framework source

Value structure

Dimensions and units

Unit
% — percentage of the compatible denominator
Reporting basis
The annual reporting period or applicable target, validation or OER cycle; base, target, cumulative and current-period observations remain separately identified.

Unit meaning: Percentage points from zero to one hundred unless the reporting method states otherwise.

Published dimensions

  • significant activity pool
  • hour or matching interval
  • deliverability region
  • target timeframe
  • applicability: Category A companies with significant electricity use; optional for Category B companies.
  • requirement level: conditional
  • SBTi Corporate Net-Zero Standard edition and transition status

Calculation method

Formula information

Status
Specified
Formula type
Percentage

Formula

(N / D) × 100

Divide the compatible hourly matched low-carbon electricity numerator by its disclosed total-population denominator for the same period and boundary, then multiply by 100.

Variables

SymbolVariableDefinitionUnit
Nhourly matched low-carbon electricity numeratorThe portion of the reporting population that satisfies the hourly matched low-carbon electricity conditionDimensionless
DCompatible denominatorThe complete eligible population for the same entity, period and reporting boundaryDimensionless

Verified sources

Evidence and status sources

Sustopedia checked each record-specific claim directly against primary publisher material. Labels distinguish current measurement authority from future compatibility and corroborative, legal, edition, or method status context. Corroborative evidence can support a stated limitation but cannot establish the core measurement by itself.

Measurement evidence

  • Measurement evidenceChecked 2 September 2026

    SBTi Corporate Net-Zero Standard Version 2.0

    Publisher
    Science Based Targets initiative
    Edition
    Corporate Net-Zero Standard Version 2.0, June 2026; effective 1 February 2027
    Locator
    C32.2, PDF page 63; C32.5, PDF pages 63, 64

    Supports: Scope 2 electricity consumption hourly matched with low-carbon electricity is a quantitative or structured result associated with C32.2, C32.5 under the stated applicability.

    Open official source

Use with context

Interpretation boundaries

Method disclosures required

Source-edition basis: Corporate Net-Zero Standard Version 2.0, June 2026; effective 1 February 2027

  • State the SBTi standard edition, applicable criterion, company category and effective or transition status.
  • State the reporting entity, boundary, population, period, unit, denominator and dimensional classifications used.
  • State estimation, conversion, exclusion, allocation, recalculation and assurance treatment where applicable.
  • Link to the official SBTi source and retain the source-defined applicability conditions.

Record-specific limitations

  • Version 2.0 becomes available for validation on 1 February 2027; Version 1.3.1 remains a distinct applicable edition through 31 January 2028.
  • The June 2026 Methods, Metrics and Pathways consultation document is not used as final formula or benchmark authority.
  • Comparability requires compatible company category, boundary, period, unit, denominator, classification and target or OER status.
  • This page is an independently authored measurement aid and does not reproduce the source standard, tables, figures or equations.

Interpret this metric with the stated reporting boundary, period convention, value shape, and unit. Results prepared with different boundaries or conventions may not be directly comparable.

Measurement evidence supports the core record-specific claims described above. Corroborative evidence can support limitations, while compatibility and status sources provide their separately labelled context. None of these cards by itself determines an organisation's legal applicability, filing readiness, assurance status, or compliance conclusion.