Light pollution indicators
Measurement answer
What this metric measures
A structured set of indicators describing contribution to light pollution through outdoor-light characteristics, output, coverage, operation and dimming.
Specification
Metric specification
- Result format
- Multi-field profile
- Unit
- Structured table — see field-level units
- Reporting basis
- Reporting period
- Aggregation
- Report each parameter separately; aggregate counts, proportions, lighting output and illuminated area only within the disclosed organizational and site boundary.
- Pillar
- Environmental
- Topic
- Pollution affecting ecosystems
- Controlled domain
- Pollution
- Entity type
- Metric
Reporting boundary
Outdoor lighting associated with the reporting organization's construction-materials activities and locations; disclose the applicable operational, site and value-chain boundary.
Verified source occurrences
Framework coverage
This is one canonical metric. The bindings below show every verified framework occurrence without creating duplicate metric pages. Edition, disclosure, role, and relationship remain source-specific.
- Adopting DisclosureSource evidence
TNFD sector guidance
- Publisher
- Taskforce on Nature-related Financial Disclosures
- Edition
- Final English sector guidance collection through August 2026 (17 documents)
- Requirement
- Not Specified
- Relationship
- Defines Disclosure
- Mapping outcome
- Direct Evidence
- Source locator
- Additional sector guidance – Construction materials, Version 1.0 (January 2025), section 3.3, Table 15, CM.A2.1, p. 69 | Additional sector guidance – Construction materials, Version 1.0 (January 2025), p. 69, section 3.3, Table 15, CM.A2.1
- Adopting DisclosureCM.A2.1
TNFD sector guidance
- Publisher
- Taskforce on Nature-related Financial Disclosures
- Edition
- Version 1.0, January 2025
- Requirement
- Recommended
- Relationship
- Maps Source Identity
- Mapping outcome
- Published
- Source locator
- Additional sector guidance – Construction materials, Version 1.0 (January 2025), p. 69, section 3.3, Table 15, CM.A2.1
Value structure
Dimensions and units
- Unit
- Structured table — see field-level units
- Reporting basis
- Reporting period
Unit meaning: Each field uses its stated unit and retains the applicable sector, reporting boundary, period and method.
Table fields and units
- location or facility
- outdoor-light parameter
- value
- unit
- BUG rating
- colour-temperature category
- illuminated area
- nighttime operating status
- dimming status or level
- measurement method and data coverage
Published dimensions
- location or facility
- outdoor-light parameter
- backlight, uplight and glare (BUG) rating
- colour-temperature threshold of more than 2700K
- lighting output
- illuminated area
- nighttime operating status
- dimming status and dimming level
Disclosure method
Formula information
- Status
- Not applicable
- Formula type
- Structured Disclosure
Disclosure form
No single formulaReport the source-defined result with its stated fields and method disclosures. CM.A2.1 is an additional-sector metric that expressly requests multiple independently reportable light-pollution parameters. It is publishable as one structured family because the fields share the same subject and boundary while retaining their differing units and measurement dimensions. It is not equivalent to the shortlisted generic management-indicator disclosure, which combines light and noise and does not preserve the specified CM.A2.1 fields.
Verified sources
Evidence and status sources
Sustopedia checked each record-specific claim directly against primary publisher material. Labels distinguish current measurement authority from future compatibility and corroborative, legal, edition, or method status context. Corroborative evidence can support a stated limitation but cannot establish the core measurement by itself.
Measurement evidence
- Measurement evidenceChecked 30 August 2026
TNFD additional sector guidance collection
- Publisher
- Taskforce on Nature-related Financial Disclosures
- Edition
- Final English sector guidance collection through August 2026 (17 documents)
- Locator
- Additional sector guidance – Construction materials, Version 1.0 (January 2025), section 3.3, Table 15, CM.A2.1, p. 69 | Additional sector guidance – Construction materials, Version 1.0 (January 2025), p. 69, section 3.3, Table 15, CM.A2.1
Supports: The official TNFD sector guidance supports the identity, boundary and method basis of “Light pollution indicators”.
Open official source
Use with context
Interpretation boundaries
Method disclosures required
Source-edition basis: TNFD sector guidance, Final English sector guidance collection through August 2026 (17 documents).
- Disclose the organizational, facility and geographic boundary covered by the outdoor-light inventory.
- Disclose the parameter definitions and units used for counts, proportions, lumens, lumens per hectare, illuminated area and dimming level.
- Disclose the BUG-rating classification approach and the treatment of lights with unavailable BUG ratings.
- Disclose the colour-temperature measurement or source-data approach and the treatment of lights exceeding 2700K.
- Disclose the definition of nighttime operation and the method used to determine whether and to what extent lighting is dimmed.
Record-specific limitations
- The source specifies a multi-parameter indicator family rather than one common scalar, so individual parameters must not be collapsed into a single light-pollution score.
- Comparability depends on disclosed lighting inventory coverage, BUG-rating availability, colour-temperature data, area measurement approach and nighttime operating definition.
- The extracted specification does not provide a single universal unit because component fields use different units.
Interpret this metric with the stated reporting boundary, period convention, value shape, and unit. Results prepared with different boundaries or conventions may not be directly comparable.
Measurement evidence supports the core record-specific claims described above. Corroborative evidence can support limitations, while compatibility and status sources provide their separately labelled context. None of these cards by itself determines an organisation's legal applicability, filing readiness, assurance status, or compliance conclusion.